{"product_id":"fluke-1777-power-quality-analyzer-basic-model-5272819","title":"Fluke 1777 Power Quality Analyzer – BASIC Model (5272819)","description":"\u003ch3 data-start=\"327\" data-end=\"345\"\u003e\u003cstrong data-start=\"331\" data-end=\"343\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"346\" data-end=\"674\"\u003eThe \u003cstrong data-start=\"350\" data-end=\"387\"\u003eFluke 1777 Power Quality Analyzer\u003c\/strong\u003e is one of the most advanced tools in Fluke’s PQ family, designed for \u003cstrong data-start=\"457\" data-end=\"544\"\u003ehigh-accuracy power quality troubleshooting, energy studies, and compliance testing\u003c\/strong\u003e.\u003cbr data-start=\"545\" data-end=\"548\"\u003eIt provides automatic measurements, powerful analytics, guided setup, and seamless reporting—all in a user-friendly interface.\u003c\/p\u003e\n\u003cp data-start=\"676\" data-end=\"787\"\u003eThe \u003cstrong data-start=\"680\" data-end=\"695\"\u003eBASIC model\u003c\/strong\u003e includes essential accessories while maintaining the same powerful measurement performance.\u003c\/p\u003e\n\u003chr data-start=\"789\" data-end=\"792\"\u003e\n\u003ch3 data-start=\"794\" data-end=\"814\"\u003e\u003cstrong data-start=\"798\" data-end=\"814\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"815\" data-end=\"1348\"\u003e\n\u003cli data-start=\"815\" data-end=\"875\"\u003e\n\u003cp data-start=\"817\" data-end=\"875\"\u003eClass A accuracy compliant with \u003cstrong data-start=\"849\" data-end=\"873\"\u003eIEC 61000-4-30 Ed. 3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"876\" data-end=\"941\"\u003e\n\u003cp data-start=\"878\" data-end=\"941\"\u003e\u003cstrong data-start=\"878\" data-end=\"909\"\u003eAutomatic measurement setup\u003c\/strong\u003e with intelligent verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"942\" data-end=\"982\"\u003e\n\u003cp data-start=\"944\" data-end=\"982\"\u003eLogs over \u003cstrong data-start=\"954\" data-end=\"980\"\u003e500 parameters at once\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"983\" data-end=\"1032\"\u003e\n\u003cp data-start=\"985\" data-end=\"1032\"\u003eHigh-resolution \u003cstrong data-start=\"1001\" data-end=\"1030\"\u003etouchscreen color display\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1033\" data-end=\"1116\"\u003e\n\u003cp data-start=\"1035\" data-end=\"1116\"\u003eMeasures harmonics, flicker, transients, dips, swells, voltage, current \u0026amp; power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1117\" data-end=\"1171\"\u003e\n\u003cp data-start=\"1119\" data-end=\"1171\"\u003eSupport for \u003cstrong data-start=\"1131\" data-end=\"1160\"\u003eFluke Energy Analyze Plus\u003c\/strong\u003e software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1172\" data-end=\"1215\"\u003e\n\u003cp data-start=\"1174\" data-end=\"1215\"\u003eCapture fast transients up to \u003cstrong data-start=\"1204\" data-end=\"1213\"\u003e8 MHz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1216\" data-end=\"1246\"\u003e\n\u003cp data-start=\"1218\" data-end=\"1246\"\u003eBattery life up to 4 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1247\" data-end=\"1288\"\u003e\n\u003cp data-start=\"1249\" data-end=\"1288\"\u003eUSB, Wi-Fi, and Ethernet connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1348\"\u003e\n\u003cp data-start=\"1291\" data-end=\"1348\"\u003eLightweight, rugged design for field and industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1350\" data-end=\"1353\"\u003e\n\u003ch3 data-start=\"1355\" data-end=\"1387\"\u003e\u003cstrong data-start=\"1359\" data-end=\"1387\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1389\" data-end=\"1900\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1389\" data-end=\"1414\"\u003e\n\u003ctr data-start=\"1389\" data-end=\"1414\"\u003e\n\u003cth data-start=\"1389\" data-end=\"1405\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1405\" data-end=\"1414\" data-col-size=\"sm\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1441\" data-end=\"1900\"\u003e\n\u003ctr data-start=\"1441\" data-end=\"1469\"\u003e\n\u003ctd data-start=\"1441\" data-end=\"1449\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1449\" data-end=\"1469\" data-col-size=\"sm\"\u003eFluke 1777 BASIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1470\" data-end=\"1495\"\u003e\n\u003ctd data-start=\"1470\" data-end=\"1484\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"1484\" data-end=\"1495\" data-col-size=\"sm\"\u003e5272819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1496\" data-end=\"1533\"\u003e\n\u003ctd data-start=\"1496\" data-end=\"1507\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"1507\" data-end=\"1533\" data-col-size=\"sm\"\u003eIEC 61000-4-30 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1534\" data-end=\"1568\"\u003e\n\u003ctd data-start=\"1534\" data-end=\"1550\" data-col-size=\"sm\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-start=\"1550\" data-end=\"1568\" data-col-size=\"sm\"\u003eUp to 1000V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1569\" data-end=\"1611\"\u003e\n\u003ctd data-start=\"1569\" data-end=\"1585\" data-col-size=\"sm\"\u003eCurrent Range\u003c\/td\u003e\n\u003ctd data-start=\"1585\" data-end=\"1611\" data-col-size=\"sm\"\u003eDepends on clamp input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1612\" data-end=\"1647\"\u003e\n\u003ctd data-start=\"1612\" data-end=\"1632\" data-col-size=\"sm\"\u003eTransient Capture\u003c\/td\u003e\n\u003ctd data-start=\"1632\" data-end=\"1647\" data-col-size=\"sm\"\u003eUp to 8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1648\" data-end=\"1689\"\u003e\n\u003ctd data-start=\"1648\" data-end=\"1664\" data-col-size=\"sm\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd data-start=\"1664\" data-end=\"1689\" data-col-size=\"sm\"\u003e256 samples per cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1690\" data-end=\"1743\"\u003e\n\u003ctd data-start=\"1690\" data-end=\"1700\" data-col-size=\"sm\"\u003eLogging\u003c\/td\u003e\n\u003ctd data-start=\"1700\" data-end=\"1743\" data-col-size=\"sm\"\u003eSimultaneous logging of 500+ parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1744\" data-end=\"1778\"\u003e\n\u003ctd data-start=\"1744\" data-end=\"1754\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1754\" data-end=\"1778\" data-col-size=\"sm\"\u003eHigh-res touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1779\" data-end=\"1818\"\u003e\n\u003ctd data-start=\"1779\" data-end=\"1794\" data-col-size=\"sm\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd data-start=\"1794\" data-end=\"1818\" data-col-size=\"sm\"\u003eUSB, Wi-Fi, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1819\" data-end=\"1859\"\u003e\n\u003ctd data-start=\"1819\" data-end=\"1830\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"1830\" data-end=\"1859\" data-col-size=\"sm\"\u003eFluke Energy Analyze Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1860\" data-end=\"1900\"\u003e\n\u003ctd data-start=\"1860\" data-end=\"1870\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"1870\" data-end=\"1900\" data-col-size=\"sm\"\u003eRechargeable Li-ion, 4 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1902\" data-end=\"1905\"\u003e\n\u003ch3 data-start=\"1907\" data-end=\"1927\"\u003e\u003cstrong data-start=\"1911\" data-end=\"1927\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1928\" data-end=\"2217\"\u003e\n\u003cli data-start=\"1928\" data-end=\"1966\"\u003e\n\u003cp data-start=\"1930\" data-end=\"1966\"\u003ePower quality compliance (Class A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1967\" data-end=\"1991\"\u003e\n\u003cp data-start=\"1969\" data-end=\"1991\"\u003eEnergy usage studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2033\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2033\"\u003eHarmonics and load imbalance analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2034\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2036\" data-end=\"2081\"\u003eTroubleshooting dips, swells, interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2082\" data-end=\"2111\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2111\"\u003eUPS and generator testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2112\" data-end=\"2144\"\u003e\n\u003cp data-start=\"2114\" data-end=\"2144\"\u003eIndustrial plant maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2145\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2147\" data-end=\"2217\"\u003eUtility, electrical contractor, and facility management applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2219\" data-end=\"2222\"\u003e\n\u003ch3 data-start=\"2224\" data-end=\"2257\"\u003e\u003cstrong data-start=\"2228\" data-end=\"2257\"\u003eIncluded in the BASIC Set\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2258\" data-end=\"2472\"\u003e\n\u003cli data-start=\"2258\" data-end=\"2289\"\u003e\n\u003cp data-start=\"2260\" data-end=\"2289\"\u003eFluke 1777 PQ Analyzer unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2290\" data-end=\"2312\"\u003e\n\u003cp data-start=\"2292\" data-end=\"2312\"\u003eVoltage test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2313\" data-end=\"2342\"\u003e\n\u003cp data-start=\"2315\" data-end=\"2342\"\u003eBasic voltage test probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2343\" data-end=\"2356\"\u003e\n\u003cp data-start=\"2345\" data-end=\"2356\"\u003eUSB cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2357\" data-end=\"2383\"\u003e\n\u003cp data-start=\"2359\" data-end=\"2383\"\u003ePower supply \u0026amp; battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2384\" data-end=\"2399\"\u003e\n\u003cp data-start=\"2386\" data-end=\"2399\"\u003eHanging kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2400\" data-end=\"2422\"\u003e\n\u003cp data-start=\"2402\" data-end=\"2422\"\u003eSoft carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2423\" data-end=\"2444\"\u003e\n\u003cp data-start=\"2425\" data-end=\"2444\"\u003eQuick start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2445\" data-end=\"2472\"\u003e\n\u003cp data-start=\"2447\" data-end=\"2472\"\u003eCalibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44630151331874,"sku":null,"price":15600000.0,"currency_code":"IQD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0842\/2090\/3458\/files\/5272819-new.png?v=1765525578","url":"https:\/\/www.matantmarket.com\/products\/fluke-1777-power-quality-analyzer-basic-model-5272819","provider":"matantalbennamarket","version":"1.0","type":"link"}