{"product_id":"fluke-1555-fc-insulation-resistance-tester-kit-10-kv-with-ir3000fc-model-4977469","title":"Fluke 1555 FC Insulation Resistance Tester Kit (10 kV) with IR3000FC – Model 4977469","description":"\u003ch3 data-start=\"402\" data-end=\"420\"\u003e\u003cstrong data-start=\"406\" data-end=\"418\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"421\" data-end=\"779\"\u003eThe \u003cstrong data-start=\"425\" data-end=\"446\"\u003eFluke 1555 FC Kit\u003c\/strong\u003e is a high-voltage \u003cstrong data-start=\"465\" data-end=\"497\"\u003einsulation resistance tester\u003c\/strong\u003e designed for industrial and utility applications.\u003cbr data-start=\"547\" data-end=\"550\"\u003eIt includes the \u003cstrong data-start=\"566\" data-end=\"604\"\u003eIR3000FC digital insulation tester\u003c\/strong\u003e and integrates \u003cstrong data-start=\"620\" data-end=\"638\"\u003eFluke Connect®\u003c\/strong\u003e for wireless data logging.\u003cbr data-start=\"665\" data-end=\"668\"\u003eThis kit allows technicians to accurately measure insulation resistance up to \u003cstrong data-start=\"746\" data-end=\"755\"\u003e10 kV\u003c\/strong\u003e safely and efficiently.\u003c\/p\u003e\n\u003chr data-start=\"781\" data-end=\"784\"\u003e\n\u003ch3 data-start=\"786\" data-end=\"806\"\u003e\u003cstrong data-start=\"790\" data-end=\"806\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"807\" data-end=\"1178\"\u003e\n\u003cli data-start=\"807\" data-end=\"845\"\u003e\n\u003cp data-start=\"809\" data-end=\"845\"\u003eInsulation testing up to \u003cstrong data-start=\"834\" data-end=\"843\"\u003e10 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"846\" data-end=\"905\"\u003e\n\u003cp data-start=\"848\" data-end=\"905\"\u003eMeasures insulation resistance, voltage, and continuity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"906\" data-end=\"956\"\u003e\n\u003cp data-start=\"908\" data-end=\"956\"\u003eIntegrated \u003cstrong data-start=\"919\" data-end=\"954\"\u003eFluke Connect® wireless logging\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"1005\"\u003e\n\u003cp data-start=\"959\" data-end=\"1005\"\u003eData storage and analysis via mobile\/desktop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1006\" data-end=\"1059\"\u003e\n\u003cp data-start=\"1008\" data-end=\"1059\"\u003eRugged, portable, and reliable for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1060\" data-end=\"1121\"\u003e\n\u003cp data-start=\"1062\" data-end=\"1121\"\u003eSafe operation with built-in protections for high voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1122\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1124\" data-end=\"1178\"\u003eIdeal for predictive maintenance and troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1180\" data-end=\"1183\"\u003e\n\u003ch3 data-start=\"1185\" data-end=\"1217\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1217\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1218\" data-end=\"1622\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1218\" data-end=\"1243\"\u003e\n\u003ctr data-start=\"1218\" data-end=\"1243\"\u003e\n\u003cth data-start=\"1218\" data-end=\"1234\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1234\" data-end=\"1243\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1270\" data-end=\"1622\"\u003e\n\u003ctr data-start=\"1270\" data-end=\"1295\"\u003e\n\u003ctd data-start=\"1270\" data-end=\"1278\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1278\" data-end=\"1295\" data-col-size=\"md\"\u003eFluke 1555 FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1296\" data-end=\"1321\"\u003e\n\u003ctd data-start=\"1296\" data-end=\"1310\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"1310\" data-end=\"1321\" data-col-size=\"md\"\u003e4977469\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1322\" data-end=\"1346\"\u003e\n\u003ctd data-start=\"1322\" data-end=\"1337\" data-col-size=\"sm\"\u003eTest Voltage\u003c\/td\u003e\n\u003ctd data-start=\"1337\" data-end=\"1346\" data-col-size=\"md\"\u003e10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1347\" data-end=\"1407\"\u003e\n\u003ctd data-start=\"1347\" data-end=\"1361\" data-col-size=\"sm\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd data-start=\"1361\" data-end=\"1407\" data-col-size=\"md\"\u003eInsulation resistance, voltage, continuity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1408\" data-end=\"1463\"\u003e\n\u003ctd data-start=\"1408\" data-end=\"1423\" data-col-size=\"sm\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd data-start=\"1423\" data-end=\"1463\" data-col-size=\"md\"\u003eFluke Connect® wireless data logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1464\" data-end=\"1489\"\u003e\n\u003ctd data-start=\"1464\" data-end=\"1474\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1474\" data-end=\"1489\" data-col-size=\"md\"\u003eBacklit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1490\" data-end=\"1525\"\u003e\n\u003ctd data-start=\"1490\" data-end=\"1499\" data-col-size=\"sm\"\u003eSafety\u003c\/td\u003e\n\u003ctd data-start=\"1499\" data-end=\"1525\" data-col-size=\"md\"\u003eCAT IV \/ CAT III rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1526\" data-end=\"1558\"\u003e\n\u003ctd data-start=\"1526\" data-end=\"1534\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"1534\" data-end=\"1558\" data-col-size=\"md\"\u003eRechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1559\" data-end=\"1622\"\u003e\n\u003ctd data-start=\"1559\" data-end=\"1574\" data-col-size=\"sm\"\u003eApplications\u003c\/td\u003e\n\u003ctd data-start=\"1574\" data-end=\"1622\" data-col-size=\"md\"\u003ePower plants, industrial plants, substations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1624\" data-end=\"1627\"\u003e\n\u003ch3 data-start=\"1629\" data-end=\"1649\"\u003e\u003cstrong data-start=\"1633\" data-end=\"1649\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1650\" data-end=\"1885\"\u003e\n\u003cli data-start=\"1650\" data-end=\"1709\"\u003e\n\u003cp data-start=\"1652\" data-end=\"1709\"\u003eInsulation resistance testing of high-voltage equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1751\"\u003e\n\u003cp data-start=\"1712\" data-end=\"1751\"\u003ePredictive and preventive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1752\" data-end=\"1797\"\u003e\n\u003cp data-start=\"1754\" data-end=\"1797\"\u003ePower generation and distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1852\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1852\"\u003eIndustrial and commercial electrical installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1853\" data-end=\"1885\"\u003e\n\u003cp data-start=\"1855\" data-end=\"1885\"\u003eSubstation equipment testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1887\" data-end=\"1890\"\u003e\n\u003ch3 data-start=\"1892\" data-end=\"1919\"\u003e\u003cstrong data-start=\"1896\" data-end=\"1919\"\u003eIncluded in the Kit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1920\" data-end=\"2078\"\u003e\n\u003cli data-start=\"1920\" data-end=\"1966\"\u003e\n\u003cp data-start=\"1922\" data-end=\"1966\"\u003eFluke 1555 FC Insulation Resistance Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1967\" data-end=\"1986\"\u003e\n\u003cp data-start=\"1969\" data-end=\"1986\"\u003eIR3000FC module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1987\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2010\"\u003eTest leads \u0026amp; probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2011\" data-end=\"2028\"\u003e\n\u003cp data-start=\"2013\" data-end=\"2028\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2050\"\u003e\n\u003cp data-start=\"2031\" data-end=\"2050\"\u003eQuick start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2051\" data-end=\"2078\"\u003e\n\u003cp data-start=\"2053\" data-end=\"2078\"\u003eCalibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44630353936418,"sku":null,"price":10800000.0,"currency_code":"IQD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0842\/2090\/3458\/files\/fluke-1555-new.jpg?v=1765526825","url":"https:\/\/www.matantmarket.com\/products\/fluke-1555-fc-insulation-resistance-tester-kit-10-kv-with-ir3000fc-model-4977469","provider":"matantalbennamarket","version":"1.0","type":"link"}